Skip to content

Guide

PoE budget explained

Short answer: add up the maximum watts of every device on the switch, keep the total under 80 % of the switch’s PoE budget, and check that each port supports the standard its device needs (PoE, PoE+ or PoE++).

Two limits on every PoE switch

A PoE switch has a total PoE budget (e.g. 370 W for all ports together) and a limit per port set by the PoE standard the port supports. A design must respect both: a 16-port switch with a 120 W budget cannot power 16 cameras at 12 W each, even though every port could.

The PoE standards

StandardNameAt the switch portAt the device
802.3afPoE (Type 1)15.4 W12.95 W
802.3atPoE+ (Type 2)30 W25.5 W
802.3bt Type 3PoE++60 W51 W
802.3bt Type 4PoE++90 W71.3 W

The difference between the switch port and the device is the power lost in up to 100 m of cable.

How to calculate it

1

List the devices

Every camera, reader, access point, phone and intercom on the switch.

2

Use the maximum watts

From each data sheet – with IR on, heater on and PTZ moving, not the typical value.

3

Add them up

The total is the PoE load of the switch.

4

Apply the 80 % rule

Choose a switch whose budget is at least the load ÷ 0.8.

5

Check each port

Devices over 15.4 W need PoE+ ports; over 30 W need PoE++ ports.

Example

8 dome cameras at 6.5 W, 4 bullet cameras with IR at 12.95 W, 1 PTZ at 25.5 W and 3 access points at 13 W: 52 + 51.8 + 25.5 + 39 = 168.3 W. With the 80 % rule the switch needs at least 211 W of PoE budget, 16 PoE ports, and PoE+ on the PTZ port.

Why keep 20 % free

  • Cameras draw more at night (IR) and in the cold (heaters).
  • Devices draw a peak when they start – after a power cut all of them start at once.
  • You will add a camera later.

Questions

Is the PoE budget the same as the switch’s power supply?

No. The power supply also runs the switch itself; the PoE budget is the part available for the ports – check it on the data sheet.

Can I use an injector instead?

Yes – a PoE+ or PoE++ injector powers one device, for example a PTZ on a switch without PoE++ ports.

Related

Let GITECHY Design do the math

Cable lengths, PoE and power budgets, batteries, voltage drop and camera coverage – on every design. One flat price per company.